| Auxiliary accessories and SSE (standard specimens of enterprise) |
| |
|
•
flat and cylindrical specimens with any parameters of "notches", "segments" and flat-bottomed
bores subject to statutory requirements of regulating documents
• filters for operation of unmatched PETs with imported and domestically produced broadband flaw detectors for
frequencies of 1.8; 2.5; 5.0 MHz
• filters for operation of unmatched PETs with imported and domestically produced broadband flaw detectors for
frequencies of 1.8; 2.5; 5.0 MHz
СР 50 - lemo 00
BNC - lemo 00
lemo 1 - lemo 00
High-frequency connecting cables for underwater control are manufactured up to 50m long
• mechanical device for UT of overlapping welded joints – UN
• mechanical device for UT of crossed welded joints – UP
• high-frequency Y-junction with an adaptor cable (for UD2-12 flaw detectors)
• auxiliary accessories for PET for hard-to-reach control zones
• PET housings with magnetic retention
• PET housings for underwater control |
| |
|
| |
|
|
Mechanical device (with two PETs) for UT of overlapping welded joints – UN1
Device "UN1", which comprises two ultrasonic transducers (45°, 4...5 MHz), a mechanical device with a
guide and a locking screw for PET -
designed for UT of overlapped welded joints of pipes, vessels, metal structures, and implements the
reflecting-shadowing control method and the echo-method.
Model "UN1" (45°) - applied for control of thicknesses within Н = 4...16 mm.
Model "UN1D" (45°) - for thicknesses within Н = 4...32 mm
Transducers feature wear-resistant working surface. The testing methodology is approved by the RF Gosgortekhnadzor. |
| |
|
|
Mechanical
device(with
two PETs)for
UT of crossed welded joints – UP1
Device "UP1", which comprises two ultrasonic transducers, a mechanical device with two guides and locking screws for PET - designed for UT of crossed welded joints in vessels and metal structures, and implements the echo-reflecting control method (asymmetrical "Duet") and echo-method (Symmetrical "Duet").
Model
"UP1" (70°) with frequency 4...5 MHz - applied for control of thicknesses within Н = 4...16 mm.
Model
"UP1" (65° и 70°) with frequency 4...5 MHz - applied for control of thicknesses Н = 8...24 mm.
Model
"UP1" (65°) with frequency 2.5 MHz - applied for control of thicknesses within Н = 12...32 mm.
Transducers feature wear-resistant working surface. The testing methodology is approved by the RF Gosgortekhnadzor.
|
| |
|
|
|
|